The MOB vacuum chamber is used for beam entry into the experimental chamber P3. The chamber was completely cleaned and assembled in the ISO 6 clean room and then subjected to an RGA test.
Project Details:
Two optical tables above each other with total usable space of 14.5 m2
Deflection, stresses and natural frequencies optimised using FEM simulation
Granite blocks with stainless steel supports as a stable foundation
Excellent stability of the chamber and optical table
Multiple access ports accurately machined after welding
Final successful RGA cleanliness measurement
About cookies and external content
For the best possible user experience, we use various services that use cookies and similar technologies. Some services are technically necessary and are providing basic functionality for this website. Others are used to analyse and improve your user experience or to provide you with certain services. For these services we need your consent, which you can withdraw at any time. Find more information regarding cookies and external content on our Data Protection Declaration and regarding us on the Legal notice.